Model |
EW-2605 |
Insulation voltage |
DC 500V |
Insulation cathode resistance |
2,5,20,50,100,200MΩ six levels |
Internal high voltage |
AC 0-5KV continuously adjustable |
Leakage current |
0.5,1.0,1.5,2.0,3.0.5.0,10,20mA |
External high voltage |
AC 0-5KV/1.5mA continuously adjustable |
Wire sensitivity |
≥10pF |
Test time |
insulation, internal and external hiah voltage time can be setarbitrarily |
Air pressure |
≤ 4Kgf/cm2 |
Foot pedal start |
Yes |
● Use Panasonic PLC control.
● Test wire type: single head: 2P non-polar, 2P click non-polar, 2P polarized, 3P non-polar.
● 3P polarized double head: 2P non-polar, 2P parallel wire, 2P cross wire, 3P parallel wire, 3P cross wire.
● Counting function: automatic counting and ejection function of qualified products and defective products.
● Qualified products are automatically ejected and qualified marks are printed; defective products are automatically mold-locked and have sound and light alarms.